Messages
ZCPU-TKN-SLICE-TRACKING-ID NonStop Blade Element tracking ID of the
affected NonStop Blade Element.
ZCMP-TKN-BMC-STATUS Indicates whether Baseboard Management
Controller (BMC) communications are
functioning normally.
ZCMP-TKN-BMC-OLDSTATUS Indicates whether BMC communications were
functioning normally.
ZCMP-TKN-FAN1-STATUS Status of the first fan (see Table 25-31
on
page 25-106).
ZCMP-TKN-FAN1-OLDSTATUS Previous status of the first fan (see Table 25-31
).
ZCMP-TKN-FAN2-STATUS Status of the second fan (see Table 25-31
).
ZCMP-TKN-FAN2-OLDSTATUS Previous status of the second fan (see
Table 25-31
).
ZCMP-TKN-FAN3-STATUS Status of the third fan (see Table 25-31
).
ZCMP-TKN-FAN3-OLDSTATUS Previous status of the third fan (see
Table 25-31
).
ZCMP-TKN-TEMP1-STATUS Status of the first temperature sensor (see
Table 25-32
).
ZCMP-TKN-TEMP1-OLDSTATUS Previous status of the first temperature sensor
(see Table 25-32
).
ZCMP-TKN-POWER1-STATUS Status of the first power supply (see
Table 25-33
).
ZCMP-TKN-POWER1-OLDSTATUS Previous status of the first power supply (see
Table 25-33
).
ZCMP-TKN-POWER2-STATUS Status of the second power supply (see
Table 25-33
).
ZCMP-TKN-POWER2-OLDSTATUS Previous status of the second power supply (see
Table 25-33
).
ZCMP-TKN-WDT-STATUS Indicates whether the BMC watchdog timer has
triggered.
ZCMP-TKN-WDT-OLDSTATUS Indicates whether the BMC watchdog timer had
triggered.
Table 25-31. ZCMP-TKN-FANn-[OLD]STATUS Values
Value Meaning
ZCMP-ENM-FAN-OK Fan is within specification.
ZCMP-ENM-FAN-NONCRITICAL One fan failed.
ZCMP-ENM-FAN-CRITICAL Both fans failed.
ZCMP-ENM-FAN-FAULT Fans are either missing or not responding.