Messages
Cause. A problem with a fan, temperature sensor, or power supply.
Effect. None.
Recovery. This is an informational message only; no corrective action is needed. 
302: ZCMP-EVT-SLICE-LED-CHANGE
LED status changed.
Table 25-32. ZCMP-TKN-TEMPn-[OLD]STATUS Values
Value Meaning
ZCMP-ENM-TEMP-OK Temperature is within specification.
ZCMP-ENM-TEMP-WARNING Temperature is near critical.
ZCMP-ENM-TEMP-CRITICAL Temperature is critical.
ZCMP-ENM-TEMP-FAULT Temperature is past critical - BMC shutdown.
ZCMP-ENM-TEMP-ACCESS-ERR Temperature access error occurred.
Table 25-33. ZCMP-TKN-POWERn-[OLD]STATUS Values
Value Meaning
ZCMP-ENM-POWER-OK Power is within specification.
ZCMP-ENM-POWER-ABSENT Power supply is either missing or not responding.
ZCMP-ENM-POWER-FAN-FAULT Power supply fan fault.
ZCMP-ENM-POWER-FAULT Power is not within specification.
ZCMP-ENM-POWER-AC-LOSS No AC power.
ZCMP-ENM-POWER-ACCESS-ERR Power supply access error occurred.
Potentially critical event: No
Action event: No
Message sender: CMAP
$ZLOG: Yes
$0: Yes