NonStop Operating System Event Management Programming Manual

Dynamic Link Library (DLL) Event Messages (ZDLL)
HP NonStop Operating System Event Management Programming Manual520372-020
26-12
Messages
Cause. See ZDLL-TKN-ERRORCODE and ZDLL-TKN-DETAIL.
Missing and mismatched timestamps indicate that ZDLL-TKN-FILE might not be the
public DLL that the ZREG file specifies.
Mismatched modification timestamps can result from moving the public DLL to the
volume SYSnn by using a mechanism (such as FTP) that does not preserve
modification timestamps.
Effect. The public DLL is not preloaded and cannot be used by programs and DLLs
that require it.
Recovery. If you modified the ZREGPTR file, the ZREG file, or the public DLL, revert
to the original files and reboot the system.
If you are using unmodified ZREGPTR and ZREG files that DSM/SCM installed, and
the public DLL is in the public DLL subvolume, contact your service provider (see
Recovery Action Requiring Vendor Support on page 26-6).
103: ZDLL-EVT-DLL-SUCCESS
The specified public DLL in the ZREG file was preloadable. Either it was preloaded, or
it was discarded because of insufficient space in the public DLL table.
ZDLL-TKN-LINK-MISG Link timestamp for the public DLL was missing from its
ZREG file specification.
ZDLL-TKN-UPDATE-EXPECTED Update timestamp that the ZREG file specified for the
public DLL.
ZDLL-TKN-UPDATE-FOUND Actual update timestamp for the public DLL.
ZDLL-TKN-UPDATE-MISG Update timestamp for the public DLL was missing from
its ZREG file specification.
ZDLL-TKN-MOD-EXPECTED Mod (modification) timestamp that the ZREG file
specified for the public DLL.
ZDLL-TKN-MOD-FOUND Actual mod (modification) timestamp for the public DLL.
ZDLL-TKN-MOD-MISG Mod (modification) timestamp for the public DLL was
missing from its ZREG file specification.
Subject: ZDLL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: PubLibsPreload_ system library procedure
Message sent to TMDS collector? No
Message sent to TMS collector? No
Token Description (page2of2)