NonStop Operating System Event Management Programming Manual
Dynamic Link Library (DLL) Event Messages (ZDLL)
HP NonStop Operating System Event Management Programming Manual—520372-020
26-18
Messages
Cause. Either:
The ZREG file’s implicit_import statement specified an export digest that did not
match the export digest of the ZIMPIMP file that was loaded for the processor.
The ZREG file’s implicit_import statement did not specify an export digest.
Indirect causes of these direct causes are:
The wrong ZREG file was used with this SYSnn subvolume.
The implicit_import statement was modified.
The ZIMPIMP file loaded in the SYSnn subvolume was replaced.
If a timestamp is missing or mismatched, the ZREG file was probably either modified or
replaced.
Effect. No public DLLs are loaded (as message 110: ZDLL-EVT-NO-PUB-DLLS on
page 26-25 reports). The processor halts with halt code %5030.
Recovery. If the problem occurred while loading the system, revert to a previously
working system image (SYSnn and ZDLLrrr subvolumes).
If you modified the ZREGPTR, ZREG, or ZIMPIMP file installed by DSM/SCM, revert to
the original files and reboot the system.
If this error occurs with the original ZREGPTR, ZREG, and ZIMPIMP files that
DSM/SCM installs, contact your service provider (see Recovery Action Requiring
Vendor Support on page 26-6).
ZDLL-TKN-UPDATE-MISG Update timestamp for the ZIMPIMP file was missing
from the implicit_import statement in the ZREG file.
ZDLL-TKN-MOD-EXPECTED Mod (modification) timestamp that the ZREG file
specified for the ZIMPIMP file in the implicit_import
statement.
ZDLL-TKN-MOD-FOUND Actual mod (modification) timestamp for the ZIMPIMP
file.
ZDLL-TKN-MOD-MISG Mod (modification) timestamp for the ZIMPIMP file was
missing from the implicit_import statement in the ZREG
file.
Token Description (page2of2)