NonStop Operating System Event Management Programming Manual
Dynamic Link Library (DLL) Event Messages (ZDLL)
HP NonStop Operating System Event Management Programming Manual—520372-020
26-24
Messages
Unconditional Tokens
Conditional Tokens
Cause. An internal preloading problem. The failure is likely to occur on all processors.
Effect. No public DLLs are loaded (as message 110: ZDLL-EVT-NO-PUB-DLLS on
page 26-25 reports). The processor halts with halt code %5030.
Recovery. Load another SYSnn subvolume. Report the values of ZDLL-TKN-
INTERNAL-ERROR and ZDLL-TKN-ERRORCODE to your service provider (see
Recovery Action Requiring Vendor Support on page 26-6).
109: ZDLL-EVT-EMPTY-ZREGPTR
The specified ZREGPTR file is empty; therefore, the SYSnn subvolume is being
treated as the public DLL subvolume.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZDLL-
EVT-PRELOAD-INTERNAL (108).
ZCPU-TKN-CPU Subject token that specifies the processor that is
reporting the event.
ZDLL-TKN-INTERNAL-ERROR Internal preload error number.
Token Description
ZDLL-TKN-ERRORCODE Error number associated with the specified
internal preload error number.
Subject: ZDLL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: PubLibsPreload_ system library procedure
Message sent to TMDS collector? No
Message sent to TMS collector? No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCPU-TKN-CPU token-type ZSPI-TYP-UINT
ZDLL-TKN-FILE <1> token-type ZSPI-TYP-STRING
Event-Message Text
Warning: File <1> is empty.