NonStop Operating System Event Management Programming Manual

Dynamic Link Library (DLL) Event Messages (ZDLL)
HP NonStop Operating System Event Management Programming Manual520372-020
26-25
Messages
Unconditional Tokens
Cause. The ZREGPTR file was empty.
Effect. The SYSnn subvolume is treated as the public DLL subvolume, which is
expected to contain the ZREG file and the public DLLs.
Recovery. If this situation was intended (that is, you deliberately bypassed DSM/SCM
to create a SYSnn subvolume containing the ZREG, public DLLs, and an empty
ZREGPTR file), no recovery is necessary.
If this situation was not intended, replace the empty ZREGPTR file (in the SYSnn
subvolume) with the DSM/SCM-generated ZREGPTR file. If your DSM/SCM-generated
ZREGPTR file is empty, contact your service provider (see Recovery Action Requiring
Vendor Support on page 26-6).
110: ZDLL-EVT-NO-PUB-DLLS
No public DLLs were preloaded.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZDLL-EVT-
EMPTY-ZREGPTR (109).
ZCPU-TKN-CPU Subject token that specifies the processor that is reporting
the event.
ZDLL-TKN-FILE Fully qualified name of the ZREGPTR file.
Subject: ZDLL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: PubLibsPreload_ system library procedure
Message sent to TMDS collector? No
Message sent to TMS collector? No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCPU-TKN-CPU token-type ZSPI-TYP-UINT
Event-Message Text
Error in preload; No public DLLs were loaded.