NonStop Operating System Event Management Programming Manual

Dynamic Link Library (DLL) Event Messages (ZDLL)
HP NonStop Operating System Event Management Programming Manual520372-020
26-26
Messages
Unconditional Tokens
Cause. Reported by a previous event, such as:
100: ZDLL-EVT-OPEN-ERR on page 26-6
104: ZDLL-EVT-NO-IMP-IMP on page 26-15
105: ZDLL-EVT-IMP-IMP-PROBLEM on page 26-16
108: ZDLL-EVT-PRELOAD-INTERNAL on page 26-23
Effect. No public DLLs are loaded. The processor halts with halt code %5030. The
failure is likely to occur on all processors.
Recovery. If the problem occurred while loading the system, revert to a previously
working system image (SYSnn and ZDLLrrr subvolumes).
If you cannot resolve the problems reported by the previous event or events, and if you
modified the public DLL subvolume, ZREG file, or ZREGPTR file, revert to the original
files and reboot the system.
If you did not modify these files, or if similar failure occurs with the original files, contact
your service provider (see Recovery Action Requiring Vendor Support on page 26-6).
111: ZDLL-EVT-NO-SCAN-MARKER
The scan marker that PLINSTL puts into a ZREG file was not found in the specified
ZREG file.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZDLL-EVT-NO-
PUB-DLLS (110).
ZCPU-TKN-CPU Subject token that specifies the processor that is reporting
the event.
Subject: ZDLL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: PubLibsPreload_ system library procedure
Message sent to TMDS collector? No
Message sent to TMS collector? No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCPU-TKN-CPU token-type ZSPI-TYP-UINT
ZDLL-TKN-FILE <1> token-type ZSPI-TYP-STRING