NonStop Operating System Event Management Programming Manual

System Monitor Event Messages (ZMON)
HP NonStop Operating System Event Management Programming Manual520372-020
7-8
Messages
Unconditional Tokens
Cause. During a system-load or reload operation, the system monitor process in the
specified processor could not open the disk file that contains the operating system
image (OSIMAGE).
Effect. The system freezes with halt code%2002.
Recovery. See the Guardian Procedure Errors and Messages Manual for the
corrective action for the file-system error (given by ZMON-TKN-FECODE).
106: ZMON-EVT-TMDS-STARTED
The TMDS TMDSAUTO program was started successfully.
Action event: No
Message sender: Monitor process
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZMON-TKN-CPU token-type ZSPI-TYP-UINT
ZMON-TKN-FECODE token-type ZSPI-TYP-ENUM
Event-Message Text
Unable to Open Operating System Image, File Error errnum
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZMON-EVT-
OSIMAGE (105)
ZMON-TKN-CPU Subject token that specifies the processor number of the
processor that is reporting the event.
ZMON-TKN-FECODE File-system error that caused this event message.
Subject: ZMON-TKN-CPU
Potentially critical event: No
Action event: No
Message sender: Monitor process
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZMON-TKN-CPU token-type ZSPI-TYP-UINT