NonStop Operating System Event Management Programming Manual
System Monitor Event Messages (ZMON)
HP NonStop Operating System Event Management Programming Manual—520372-020
7-23
Messages
Cause. A PROCESS_CREATE_ error occurred when the system monitor attempted to 
start the OSS socket transport agent.
Effect. The OSS socket transport agent does not start. The system continues running 
with OSS sockets disabled.
Recovery. See the description of PROCESS_CREATE_ errors in the Guardian 
Procedure Errors and Messages Manual for detailed information on the specified error 
and error detail.
The program file for the OSS socket transport agent is $SYSTEM.SYSnn. OSSTA, 
where nn is a two-digit octal integer that identifies the subvolume from which the 
system was loaded. It is run with a process name of $ZTAnn, where nn is the 
processor number.
Take the corrective action needed to allow this program to run. The preferred recovery 
action is to reload or reboot the processor in which the startup failed. The system 
monitor then automatically attempts a restart.
A less desirable alternative is to restart the OSS socket transport agent manually by 
logging on as the super ID and running the OSSTA program in the desired processor 
with the process name of $ZTAnn, where nn is the processor number. 
ZSPI-TKN-PROC-ERR Contains ZGRD-VAL-PROCESS-CREATE to 
indicate a process-creation error.
ZGRD-TKN-ERRORCODE PROCESS_CREATE_ error value. This value is 
a decimal number indicating the outcome of the 
process-creation attempt. See the Guardian 
Procedure Errors and Messages Manual for the 
possible error values.
ZGRD-TKN-ERRORDETAIL PROCESS_CREATE_ error detail value. This 
value is a decimal number containing additional 
information about some classes of errors. See 
the Guardian Procedure Errors and Messages 
Manual to determine whether the detail is 
meaningful for the error encountered.
Token Description