NonStop Operating System Event Management Programming Manual
System Clock Event Messages (ZCLK)
HP NonStop Operating System Event Management Programming Manual—520372-020
8-8
Messages
Unconditional Tokens
Cause. System time was automatically reset because of a DST change.
Effect. The event-generation timestamp on the message indicates the new system
time.
Recovery. This is an informational message only; no corrective action is needed.
101: ZCLK-EVT-CLOCKSETFROMRMI (D-Series) or
ZCLK-EVT-CLOCKSETFROMSP (G-Series and H-Series)
System time was set from the Remote Maintenance Interface (RMI) clock (on D-series
NonStop operating system RVUs) or from the SP clock (on G-series and H-Series
NonStop operating system RVUs).
Message sender: Monitor process
TMDS collector: Yes
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-SYSCLOCK token-type ZSPI-TYP-UINT
Event-Message Text
SYSTEM TIME RESET DUE TO DST TRANSITION
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCLK-EVT-
TIMERESETDST (100).
ZCLK-TKN-SYSCLOCK Subject token that specifies the system time event.
Subject: ZCLK-TKN-SYSCLOCK
Potentially critical event: No
Action event: No
Message sender: SETSYSTEMCLOCK procedure
TMDS collector: Yes
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-SYSCLOCK token-type ZSPI-TYP-UINT