NonStop Operating System Event Management Programming Manual
System Clock Event Messages (ZCLK)
HP NonStop Operating System Event Management Programming Manual—520372-020
8-10
Messages
Unconditional Tokens
(Pre-D20 version) The following four tokens form the fixed value of the difference in
time between system time and the time requested by the SETSYSTEMCLOCK
procedure:
(D20 and later version) ZCLK-TKN-INTERVAL-WORD is the token that specifies the
difference in time between system time and the time requested by the
SETSYSTEMCLOCK procedure.
Cause. One of the following situations occurred:
The operator issued a SETTIME command to set the system time, and the
difference between the current system time and the new setting was greater than 2
minutes.
The operator issued a SETTIME command twice within 10 seconds.
Effect. None.
Recovery. This is an informational message only; no corrective action is needed.
103: ZCLK-EVT-TIMESETMEAS
The system time was changed while a Measure measurement was active.
Unconditional Tokens (D20 and later)
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-SYSCLOCK token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-WORD token-type ZSPI-TYP-INT4
Event-Message Text
SYSTEM CLOCK RESET
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCLK-EVT-
TIMERESET (102).
ZCLK-TKN-SYSCLOCK Subject token that specifies that this is a system time event.
Token Description
ZCLK-TKN-INTERVAL-W-0 Word 0 of the fixed value.
ZCLK-TKN-INTERVAL-W-1 Word 1 of the fixed value.
ZCLK-TKN-INTERVAL-W-2 Word 2 of the fixed value.
ZCLK-TKN-INTERVAL-W-3 Word 3 of the fixed value.
Subject: ZCLK-TKN-SYSCLOCK
Potentially critical event: No
Action event: No