NonStop Operating System Event Management Programming Manual
System Clock Event Messages (ZCLK)
HP NonStop Operating System Event Management Programming Manual—520372-020
8-11
Messages
Cause. The system time was changed while a Measure measurement was active.
Changing the system time invalidates the measurement.
Effect. Certain measure counters might be invalid.
Recovery. This is an informational message only; no corrective action is needed.
104: ZCLK-EVT-CLOCKREADFAILED
An error occurred while the system was attempting to read the Remote Maintenance
Interface (RMI) clock (on D-series NonStop operating system RVUs) or the SP clock
(on G-series and H-series NonStop operating system RVUs).
Message sender: SETSYSTEMCLOCK procedure
TMDS collector: Yes
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-SYSCLOCK token-type ZSPI-TYP-UINT
Event-Message Text
SYSTEM CLOCK RESET DURING MEASUREMENT
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCLK-EVT-
TIMESETMEAS (103).
ZCLK-TKN-SYSCLOCK Subject token that specifies that this is a system time event.
Subject: ZCLK-TKN-RMICLOCK (D-series)
ZCLK-TKN-SPCLOCK (G-series and H-series)
Potentially critical event: Yes
Action event: No
Message sender: SETSYSTEMCLOCK procedure or the system monitor
TMDS collector: Yes
OSM/TSM collector: Yes
Unconditional Tokens (pre-D20)
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-RMICLOCK token-type ZSPI-TYP-UINT
ZCLK-TKN-RMIIOERROR token-type ZSPI-TYP-ENUM
ZCLK-TKN-INTERVAL-W-0 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-1 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-2 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-3 token-type ZSPI-TYP-UINT