NonStop Operating System Event Management Programming Manual

System Clock Event Messages (ZCLK)
HP NonStop Operating System Event Management Programming Manual520372-020
8-18
Messages
Cause. A request was passed to the SETSYSTEMCLOCK procedure to update the
time. An initial check determined that the difference between the current time and the
new time was small enough that an adjustment could be set up to correct the clock
over time (instead of resetting the clock). This adjustment was started.
Effect. The time is adjusted.
Recovery. This is an informational message only; no corrective action is needed.
108: ZCLK-EVT-OUTOFSYNC
A processor is no longer synchronized with system time.
Unconditional Tokens
Subject: ZCLK-TKN-CPU
Potentially critical event: No
Action event: No
Message sender: Monitor process
TMDS collector: Yes
OSM/TSM collector: Yes
Unconditional Tokens (pre-D20)
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-CPU token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-0 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-1 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-2 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-3 token-type ZSPI-TYP-UINT
Unconditional Tokens (D20 and later)
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-CPU token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-WORD token-type ZSPI-TYP-INT4
Event-Message Text
CPU CLOCK IS NOT SYNCHRONIZED WITH SYSTEM TIME
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCLK-EVT-
OUTOFSYNC (108).
ZCLK-TKN-CPU Subject token that specifies the processor number of the
processor that is no longer synchronized.