NonStop Operating System Event Management Programming Manual
System Clock Event Messages (ZCLK)
HP NonStop Operating System Event Management Programming Manual—520372-020
8-20
Messages
Unconditional Tokens
(Pre-D20 version) The following four tokens form the fixed-point value of the difference
in time between system time and the processor’s local time:
(D20 and later version) ZCLK-TKN-INTERVAL-WORD specifies the difference in time
between system time and the processor’s local time.
Cause. A processor has lost and regained power. Its clock has been re synchronized
with system time.
Effect. None.
Recovery. This is an informational message only; no corrective action is needed.
Unconditional Tokens (pre-D20)
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-CPU token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-0 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-1 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-2 token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-W-3 token-type ZSPI-TYP-UINT
Unconditional Tokens (D20 and later)
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-CPU token-type ZSPI-TYP-UINT
ZCLK-TKN-INTERVAL-WORD token-type ZSPI-TYP-INT4
Event-Message Text
CPU CLOCK RESYNCHRONIZED WITH SYSTEM TIME DURING POWERFAIL
RECOVERY
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCLK-EVT-
PONRESYNC (109).
ZCLK-TKN-CPU Subject token that specifies the processor number of the
processor whose time has been adjusted.
Token Description
ZCLK-TKN-INTERVAL-W-0 Word 0 of the fixed value.
ZCLK-TKN-INTERVAL-W-1 Word 1 of the fixed value.
ZCLK-TKN-INTERVAL-W-2 Word 2 of the fixed value.
ZCLK-TKN-INTERVAL-W-3 Word 3 of the fixed value.