NonStop Operating System Event Management Programming Manual

System Clock Event Messages (ZCLK)
HP NonStop Operating System Event Management Programming Manual520372-020
8-22
Messages
(D20 and later version) ZCLK-TKN-INTERVAL-WORD specifies the difference in time
between system time and the processor’s local time.
Cause. The difference between the processor time and system time has become
small enough to claim that this processor is synchronized.
Effect. Processes running in the processor obtain timestamps that are within 100
milliseconds of the system time.
Recovery. This is an informational message only; no corrective action is needed.
111: ZCLK-EVT-RMIOUTOFSYNC (D-Series) or
ZCLK-EVT-SPOUTOFSYNC (G-Series and H-Series)
The difference between the Remote Maintenance Interface (RMI) clock time or the SP
clock time and system time is large enough to consider the RMI clock or the SP clock
time to be out of synchronization. A RESETRMICLOCK or a RESETSPCLOCK
instruction is initiated.
Subject: ZCLK-TKN-RMICLOCK (D-series)
ZCLK-TKN-SPCLOCK (G-series and H-series)
Potentially critical event: No
Action event: No
Message sender: Monitor process
TMDS collector: Yes
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZCLK-TKN-RMICLOCK token-type ZSPI-TYP-UINT *
ZCLK-TKN-INTERVAL-WORD token-type ZSPI-TYP-INT4
ZCLK-TKN-SPCLOCK token-type ZSPI-TYP-UINT **
Event-Message Text (D-Series)
RMI CLOCK IS NOT SYNCHRONIZED WITH SYSTEM TIME
Event-Message Text (G-Series)
SP CLOCK IS NOT SYNCHRONIZED WITH SYSTEM TIME
* D-series
** G-series and H-series