NonStop Operating System Event Management Programming Manual
System Clock Event Messages (ZCLK)
HP NonStop Operating System Event Management Programming Manual—520372-020
8-24
Messages
Unconditional Tokens
Cause. When trying to set the system clock after a power failure, the RMI or the SP 
detected a large time discrepancy between the values from the RMI or the SP clock 
and the system clock.
Effect. The system clock time continues from the time of the power failure and does 
not include the time that power was off.
Recovery. Enter a SETTIME command to set the correct system time. If the RMI or 
the SP clock has failed, see Recovery Action Requiring Vendor Support on page 8-7. 
Event-Message Text (G-Series, H-Series)
SP CLOCK INVALID WHEN TRYING TO RESET SYSTEM CLOCK AFTER 
POWER FAILURE
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCLK-EVT-
SYSCLOCKSETFAILED (112).
ZCLK-TKN-SYSCLOCK Subject token that specifies the time value of the system 
clock.
ZCLK-TKN-INTERVAL-WORD Difference in time between system time and RMI clock 
time.










