NonStop Operating System Event Management Programming Manual
Labeled-Tape Server Events Messages (ZTAP)
HP NonStop Operating System Event Management Programming Manual—520372-020
9-122
Messages
702: ZTAP-EVT-DOWNREVMDBM
The local MEDIADBM program has an incompatible version.
Unconditional Tokens
Cause. The MEDIADBM program in the same subvolume as $ZSVR has an
incompatible version. The request that $ZSVR just sent to MEDIADBM could not be
completed.
Effect. If $ZSVR was attempting to use MEDIADBM for an application request for a
tape, the application receive a file-system error 594.
Recovery. Install a compatible version of MEDIADBM.
Subject: ZTAP-TKN-DEV-NAME
Potentially critical event: No
Action event: No
Message sender: $ZSVR
TMDS collector: No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZEMS-TKN-ACTION-NEEDED token-type ZSPI-TYP-BOOLEAN
ZEMS-TKN-ACTION-ID token-type ZSPI-TYP-INT
ZTAP-TKN-DEV-NAME token-type ZSPI-TYP-DEVICE
Event-Message Text
ERROR 1039 - LOCAL MEDIADBM VERSION IS INCOMPATIBLE WITH
ZSERVER
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZTAP-EVT-
DOWNREVMDBM (702).
ZEMS-TKN-ACTION-
NEEDED
Has the value ZSPI-VAL-FALSE.
ZEMS-TKN-ACTION-ID $ZSVR internal message number that identifies the
request. This token contains a four-digit number ranging
from 0000 through 9999.
ZTAP-TKN-DEV-NAME Subject token that specifies the device name.