NonStop Operating System Event Management Programming Manual
Tape Process Event Messages (ZTAP)
HP NonStop Operating System Event Management Programming Manual—520372-020
10-95
Messages
289: ZTAP-EVT-SYN-SCSI-BUS-IN
A SCSI-bus reset was initiated by a person or another device on the same bus.
Unconditional Tokens
Cause. A SCSI bus becomes nonresponsive (hung).
Effect. The current operation fails.
Recovery. The reset causes the operation to be retried.
300: ZTAP-EVT-DATA-CORRECTED
A correctable data error occurred.
Subject: ZEMS-TKN-LDEVNUMBER
Potentially critical event: No
Action event: No
Message sender: Tape process
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM
ZEMS-TKN-XLDEVNAME token-type ZSPI-TYP-STRING
ZEMS-TKN-LDEVNUMBER token-type ZSPI-TYP-INT2
Event-Message Text
$tapenn SMD scsi bus reset in, LDEV $nn
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZTAP-EVT-SYN-
SCSI-BUS-IN (289).
ZEMS-TKN-XLDEVNAME Subject token that specifies the name of the tape device in
the form $nnnn.
ZEMS-TKN-LDEVNUMBER Subject token that specifies the logical device number in
the form $nn.
Subject: ZTAP-TKN-DEV-NAME
Potentially critical event: No
Action event: No
Message sender: Tape process
TMDS collector: Yes