NonStop Operating System Event Management Programming Manual
Tape Process Event Messages (ZTAP)
HP NonStop Operating System Event Management Programming Manual—520372-020
10-99
Messages
Unconditional Tokens
Cause. An EIO instruction was issued, and the TERMSTAT returned indicates that a
data-path parity error occurred. This event message can indicate a problem with the
drive, formatter, controller, or channel. TERMSTAT values are:
Effect. The tape operation aborts.
ZTAP-TKN-PIN token-type ZSPI-TYP-UINT
ZTAP-TKN-LDEV token-type ZSPI-TYP-UINT
ZTAP-TKN-DEV-TYPE token-type ZSPI-TYP-BYTE-PAIR
ZTAP-TKN-UNIT-ADR token-type ZSPI-TYP-UINT
ZEMS-MAP-EXIOADDR token-type ZSPI-DDL-EXIOADDR
ZTAP-TKN-CNTLR-SHARED token-type ZSPI-TYP-BOOLEAN
ZTAP-TKN-EIO-LAC token-type ZSPI-TYP-UINT
ZTAP-TKN-EIO-LPRM token-type ZSPI-TYP-UINT
ZTAP-TKN-EIO-RDST token-type ZSPI-TYP-UINT
ZTAP-TKN-EIO-CHANSTAT token-type ZSPI-TYP-UINT
ZTAP-TKN-IIO-RIC token-type ZSPI-TYP-UINT
ZTAP-TKN-IIO-RIST token-type ZSPI-TYP-UINT
ZTAP-TKN-IIO-CHANSTAT token-type ZSPI-TYP-UINT
ZTAP-TKN-IOC-COUNT token-type ZSPI-TYP-UINT
ZTAP-TKN-IOC-RESIDUE token-type ZSPI-TYP-UINT
ZTAP-TKN-TAPE-VOLUME token-type ZTAP-TYP-TAPE-VOLUME
ZTAP-TKN-DEV-STATUS token-type ZSPI-TYP-UINT
Event-Message Text
dev-name DATA PATH PARITY ERROR, LDEV $ldev,
SUBCHANNEL ADDRESS %unit-addr
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZTAP-EVT-D-
PATH-PARITY-ERROR (302).
ZTAP-TKN-DEV-NAME Subject token that specifies the name of the tape device in
the form $nnnn.
Controller TERMSTAT
3206 (No event)
3207 (No event)
3208 58
3209 (No event)
3211 (No event)
3214 (No event)
3215 (No event)
3681 (No event)