NonStop Operating System Event Management Programming Manual

Disk Process Event Messages (ZDSK)
HP NonStop Operating System Event Management Programming Manual520372-020
11-3
-1034: ZDSK-EVT-SK-DEFERED-ERROR* Some error has already occurred and
most likely this indicates that a write of
the disk drive's internal cache did not
succeed.
000449: ZDSK-EVT-BLK-REWRITTEN
*
A checksum error was detected on one
disk drive of a mirrored volume, but
was successfully read from the other
disk drive. In order to provide the
highest data availability, DP2 Driver has
rewritten the good block back out to the
disk drive that returned the checksum
error.
000450: ZDSK-EVT-MISCOMPARE-RDWR
*
After writing a block to the disk, the
DP2 Driver read it back and found that
the data did not compare.
5001: ZDSK-EVT-ACTION-TAKEN
*
An I/O attempt failed because of a path
or media error, and the disk process
has taken a specific action.
5003: ZDSK-EVT-BAD-FST
The disk process detected an invalid
free space table (FST).
5005: ZDSK-EVT-BAD-MIRROR-VOLS
*
The primary and mirror disks of a
mirrored volume are inconsistent.
5008: ZDSK-EVT-BAD-UNDO-AREA
The disk process encountered an
invalid undo area.
5010: ZDSK-EVT-BAD-VLAB-SECT
The volume label contained invalid
data.
5011: ZDSK-EVT-BAD-VOL-NAME
The disk process encountered an
unusable disk volume name.
5012: ZDSK-EVT-BADDOWN-TMF
The disk process can no longer accept
requests for audited files.
5015: ZDSK-EVT-DRV-DOWN
*
The specified path was placed in the
down state.
5016: ZDSK-EVT-ERR-ELEM
*
An error occurred on a disk during a
disk process elementary command.
5017: ZDSK-EVT-DRV-ERR-EXT
*
An error occurred on disk during a disk
process extended command.
5018: ZDSK-EVT-DRV-UP
*
The specified path was placed in the up
state.
5019: ZDSK-EVT-EXCEPT-ERR-ELEM
*
An exception error occurred on a disk
during a disk process elementary
command.
Table 11-1. Disk Process Event Messages (page 3 of 9)
* Generated by the DP2 Driver (T9753)