Unconditional Tokens
Cause. The default debugger might have terminated.
Effect. The process requiring debug services resumes.
Recovery. This is an informational message only; no corrective action is needed.
118: ZNSK-EVT-DFLT-DBGR-TIMEOUT
The default debugger did not register with Debug Services in the expected timeframe.
Event-Message Text
Debug Services encountered an IO error with the default
debugger
Token Description
ZNSK-TKN-FILE Subject token that specifies the name of the file that was to
be debugged.
ZNSK-TKN-CPU Processor number of the processor on which Debug
Services encountered the I/O error.
ZNSK-TKN-PIN Process identification number of the processor on which
Debug Services encountered the I/O error.
ZNSK-TKN-ERRORDETAIL Error detail code of the error that occurred.
Subject: ZNSK-EVT-DFLT-DBGR-TIMEOUT
Potentially critical event: No
Action event: No
Message sender: Debug Monitor (ZDBGMON)
$ZLOG: No
$0: Yes
Unconditional Tokens
ZNSK-TKN-FILE token-type ZSPI-TYP-STRING
ZNSK-TKN-CPU token-type ZSPI-TYP-INT
ZNSK-TKN-PIN token-type ZSPI-TYP-UINT
Event-Message Text
Debug Services encountered an IO error with the default