Messages
Unconditional Tokens
Cause. A file-system error occurred during an attempt to open the indicated SRL.
Effect. ZTILT process creation is terminated, and no public SRLs are loaded.
Recovery. Ensure that the object file is actually the required SRL object file, and if it is
not, install the correct object file. For a description of the given error, see the Guardian
Procedure Errors and Messages Manual.
If the error persists after you correct the situation, the SRL object file is unusable. See
Recovery Action Requiring Vendor Support on page 14-9.
110: ZSRL-EVT-SRL-NAME-EDIT-ERR
A file-system error occurred during an attempt to locate the SRL or construct its name.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSRL-EVT-SRL-
OPEN-ERR (109).
ZSRL-TKN-CPU Subject token that specifies the processor number of the
processor that is reporting the error.
ZSRL-TKN-FECODE File-system error number.
ZSRL-TKN-FILE Name of the ZTILT program file.
Subject: ZSRL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: ZTILT_CREATE_ library procedure
TMDS collector: No
OSM/TSM collector: No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSRL-TKN-CPU token-type ZSPI-TYP-UINT
ZSRL-TKN-FECODE token-type ZSPI-TYP-INT
ZSRL-TKN-FILE token-type ZSPI-TYP-STRING
Event-Message Text
File Error file-err constructing name of SRL object file
filename.