NonStop Operating System Event Management Programming Manual

Shared Run-Time Library (SRL) Event Messages
(ZSRL)
HP NonStop Operating System Event Management Programming Manual520372-020
14-22
Messages
Unconditional Tokens
Cause. A file-system error occurred during an attempt to locate a position within the
indicated SRL.
Effect. ZTILT process creation is terminated, and no public SRLs are loaded.
Recovery. Check to ensure that the appropriate SRL object file has been placed in the
$SYSTEM.SYSnn subvolume you are loading from and that your installation
procedures have been followed completely. For a description of the given error, see the
Guardian Procedure Errors and Messages Manual.
If the error persists after you correct the situation, the SRL object file is unusable. See
Recovery Action Requiring Vendor Support on page 14-9.
113: ZSRL-EVT-SRL-TANDEM-INFO-ERR
The specified SRL object file does not contain the TANDEM_INFO section.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSRL-EVT-SRL-
READ-ERR (112).
ZSRL-TKN-CPU Subject token that specifies the processor number of the
processor that is reporting the error.
ZSRL-TKN-FECODE File-system error number.
ZSRL-TKN-FILE Name of the ZTILT program file.
Subject: ZSRL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: ZTILT_CREATE_ library procedure
TMDS collector: No
OSM/TSM collector: No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSRL-TKN-CPU token-type ZSPI-TYP-UINT
ZSRL-TKN-FILE token-type ZSPI-TYP-STRING
ZSRL-TKN-MODSTAMP token-type ZSPI-TYP-STRING
ZSRL-TKN-FILEEOF token-type ZSPI-TYP-INT2
Event-Message Text
File header does not contain the TANDEM_INFO section in SRL
file filename OBJ GMT: modstamp EOF: eof.