NonStop Operating System Event Management Programming Manual

Shared Run-Time Library (SRL) Event Messages
(ZSRL)
HP NonStop Operating System Event Management Programming Manual520372-020
14-26
Messages
Unconditional Tokens
Cause. The indicated SRL object file was not built as an SRL.
Effect. ZTILT process creation is terminated, and no public SRLs are loaded.
Recovery. Check to ensure that the appropriate SRL object file has been placed in the
$SYSTEM.SYSnn subvolume you are loading from and that your installation
procedures have been followed completely.
If the error persists after you correct the situation, the SRL object file is unusable. See
Recovery Action Requiring Vendor Support on page 14-9.
117: ZSRL-EVT-ZTILT-START-ERR
A PROCESS_CREATE_ error occurred during an attempt to create the ZTILT process.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSRL-EVT-SRL-
FLAG-ERR (116).
ZSRL-TKN-CPU Subject token that specifies the processor number of the
processor that is reporting the error.
ZSRL-TKN-FILE Name of the ZTILT program file.
ZSRL-TKN-MODSTAMP Modification timestamp of the ZTILT file in GMT.
ZSRL-TKN-FILEEOF EOF value for the ZTILT file.
Subject: ZSRL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: ZTILT_CREATE_ library procedure
TMDS collector: No
OSM/TSM collector: No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSRL-TKN-CPU token-type ZSPI-TYP-UINT
ZSRL-TKN-ERRORCODE token-type ZSPI-TYP-INT
ZSRL-TKN-ERRORDETAIL token-type ZSPI-TYP-INT
Event-Message Text
Failure starting ZTILT. Process_Create_ error pc-error, error
detail err-detail.