NonStop Operating System Event Management Programming Manual

Shared Run-Time Library (SRL) Event Messages
(ZSRL)
HP NonStop Operating System Event Management Programming Manual520372-020
14-37
Messages
Recovery. Examine the file-system error and the specified ZTILT object file to
determine the cause of the error and attempt to correct the problem. For a description
of the given error, see the description of file-system errors in the Operator Messages
Manual. For more detailed information including recovery actions, see the Guardian
Procedure Errors and Messages Manual. Locate the ZTILT object file, install it, and
reload the system or processor.
If the error persists, See Recovery Action Requiring Vendor Support on page 14-9.
128: ZSRL-EVT-SRL-SECUR-ERR
The ZTILT process was not created because an SRL object file is not owned by the
super ID.
Unconditional Tokens
Cause. The public SRL object file was not owned by the super ID (255, 255). The
public SRL object file must be owned by the super ID in order to successfully load
public SRLs.
Effect. ZTILT process creation is terminated, and no public SRLs are loaded.
Recovery. Ensure that the public SRL object file is owned by the super ID (255, 255),
then reload the affected system or processor.
Subject: ZSRL-TKN-CPU
Potentially critical event: Yes
Action event: No
Message sender: ZTILT_CREATE_ library procedure
TMDS collector: No
OSM/TSM collector: No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSRL-TKN-CPU token-type ZSPI-TYP-UINT
ZSRL-TKN-FILE token-type ZSPI-TYP-STRING
Event-Message Text
SUPER.SUPER access required for SRL object object-file.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSRL-EVT-SRL-
SECUR-ERR (128).
ZSRL-TKN-CPU Subject token that specifies the processor number of the
processor that is reporting the error.
ZSRL-TKN-FILE Name of the ZTILT program file.