NonStop Operating System Event Management Programming Manual
XIO Subsystem Event Messages (ZXIO)
HP NonStop Operating System Event Management Programming Manual—520372-020
15-12
Messages
Unconditional Tokens
Cause. The ICEPACK setup response timed out.
Effect. The ICEPACK was not set up properly.
Recovery. This event is generated as a result of a hardware problem. Check the
indicated hardware. If the error persists, see Recovery Action Requiring Vendor
Support on page 15-6.
106: ZXIO-EVT-MT-CREATE-FAIL
An attempted to expand the module table failed.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZXIO-EVT-PKT-
SETUP-TIMEOUT (105).
ZEMS-TKN-XLDEVNAME Subject token that specifies the subsystem name for this
event.
ZXIO-TKN-SNET-ID ServerNet ID of the ICEPACK.
ZXIO-TKN-SNET-DEV-HANDLE ServerNet device handle.
ZXIO-TKN-ADAPTER-NAME Adapter name that corresponds to the SAC in this event.
Subject: ZEMS-TKN-XLDEVNAME
Potentially critical event: Yes
Action event: No
Message sender: XIOMON
TMDS collector: No
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZEMS-TKN-XLDEVNAME token-type ZSPI-TYP-STRING
ZXIO-TKN-MT-SIZE token-type ZSPI-TYP-INT2
Event-Message Text
Error in allocating space for module table having nnn
entries.