NonStop Operating System Event Management Programming Manual
Nonstop Operating System Message System Event
Messages (ZIPC)
HP NonStop Operating System Event Management Programming Manual—520372-020
16-14
Messages
Recovery. This is an informational message only; no corrective action is needed.
101: ZIPC-EVT-DET-BAD-PKT-RCVD
A ServerNet error has been detected on the indicated path.
Unconditional Tokens
Subject: ZIPC-TKN-PROBLEM-CPU
Potentially critical event: No
Action event: No
Message sender: Monitor process
TMDS collector: No
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM
ZIPC-TKN-REPORTING-CPU token-type ZSPI-TYP-UINT
ZIPC-TKN-PROBLEM-CPU token-type ZSPI-TYP-UINT
ZIPC-TKN-PATH token-type ZSPI-TYP-ENUM
ZIPC-TKN-RCVD-PKT-STATUS token-type ZSPI-TYP-ENUM
ZIPC-TKN-TR-TYPE token-type ZSPI-TYP-ENUM
ZIPC-TKN-SNET-ADDR-USED token-type ZSPI-TYP-INT2
ZIPC-TKN-BYTE-COUNT-USED token-type ZSPI-TYP-INT2
Conditional Token
ZIPC-TKN-PROBLEM-NODE token-type ZSPI-TYP-UINT
Event-Message Text
Bad ServerNet packet received on the path path by processor
reporting-cpu from processor problem-cpu {in ServerNet node
node-number}.
Details of the bad packet are:
Status of packet: packet-status
ServerNet transaction type: tr-type
ServerNet address used: snet-addr
Bytecount in packet: byte-count
Token Description (page 1 of 2)
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZIPC-EVT-
DET-BAD-PKT-RCVD (101).
ZIPC-TKN-REPORTING-CPU Processor number of the processor on which the error
was detected.
ZIPC-TKN-PROBLEM-CPU Subject token that specifies the processor in which the
message originated.
ZIPC-TKN-PATH Fabric over which the message was transmitted.