NonStop Operating System Event Management Programming Manual

Nonstop Operating System Message System Event
Messages (ZIPC)
HP NonStop Operating System Event Management Programming Manual520372-020
16-23
Messages
112: ZIPC-EVT-FABRIC-DOWN
The reporting processor’s connection to the ServerNet fabric has failed or been
brought down.
Unconditional Tokens
Cause. The reporting processors connection to the indicated ServerNet fabric was
brought down.
Effect. The processor no longer attempts to communicate with the rest of the system
or ServerNet cluster via the indicated fabric.
Recovery. If the fabric went down because of:
A hardware problem—correct the problem then bring the fabric up using the SCF
START SERVERNET command.
An operator (SCF) command—bring the fabric up using the SCF START
SERVERNET command.
Subject: ZIPC-TKN-PROBLEM-CPU
Potentially critical event: Yes
Action event: Yes
Message sender: Monitor process
TMDS collector: Yes
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM
ZIPC-TKN-REPORTING-CPU token-type ZSPI-TYP-UINT
ZIPC-TKN-PATH token-type ZSPI-TYP-ENUM
ZIPC-TKN-PATH-REASON token-type ZSPI-TYP-ENUM
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN
Event-Message Text
Processor reporting-cpu has lost connectivity to the path
fabric due to path-reason.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZIPC-EVT-
FABRIC-DOWN (112).
ZIPC-TKN-REPORTING-CPU Processor number of the processor that reports the
problem.
ZIPC-TKN-PATH Fabric to which connectivity has been lost.
ZIPC-TKN-PATH-REASON Reason that connectivity was lost.
ZEMS-TKN-EMPHASIS Always true for this event.