NonStop Operating System Event Management Programming Manual
Nonstop Operating System Message System Event
Messages (ZIPC)
HP NonStop Operating System Event Management Programming Manual—520372-020
16-24
Messages
113: ZIPC-EVT-FABRIC-UP
The reporting processor has recovered its connection to the ServerNet fabric.
Unconditional Tokens
Cause. Connectivity between the indicated processor and the fabric has been
restored.
Effect. The processor is able to again communicate with other system components via
this fabric.
Recovery. This is an informational message only; no corrective action is needed.
Subject: ZIPC-TKN-PROBLEM-CPU
Potentially critical event: No
Action event: No
Message sender: Monitor process
TMDS collector: No
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM
ZIPC-TKN-REPORTING-CPU token-type ZSPI-TYP-UINT
ZIPC-TKN-PATH token-type ZIPC-TYP-ENUM
ZIPC-TKN-PATH-REASON token-type ZIPC-TYP-ENUM
Event-Message Text
Processor reporting-cpu has recovered connectivity to the
path fabric due to path-reason.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZIPC-EVT-
FABRIC-UP (113).
ZIPC-TKN-REPORTING-CPU Processor number of the processor that has just regained
connectivity.
ZIPC-TKN-PATH Fabric to which the reporting processor has regained
connectivity.
ZIPC-TKN-PATH-REASON Reason connectivity was regained.