Unconditional Tokens
Cause. An internal boundary tag is invalid.
Effect. The primary process fails. Data might be corrupted.
Recovery. If the backup process does not detect the same error, no recovery action is
needed. If the backup process detects the same error, the process fails. See Recovery
Action Requiring Vendor Support on page 18-7.
29: ZNSC-EVT-EYECATCHER-FATAL
An invalid block identifier was detected.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZNSC-EVT-
BOUNDARY-FATAL (28).
ZNSC-TKN-PROC-NAME Subject token that specifies the process name of the
process using NSC.
ZNSC-TKN-ADDRESS Address of the failed boundary tag.
ZNSC-TKN-TASK-NAME Name of the active task when the error occurred.
Subject: ZNSC-TKN-PROC-NAME
Potentially critical event: No
Action event: No
Message sender: Processes using NSC
TMDS collector: No
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZNSC-TKN-PROC-NAME token-type ZSPI-TYP-STRING
ZNSC-TKN-ADDRESS token-type ZSPI-TYP-INT2
ZNSC-TKN-TASK-NAME token-type ZSPI-TYP-STRING
ZNSC-TKN-EYECATCHER token-type ZSPI-TYP-STRING
ZNSC-TKN-TEXT token-type ZSPI-TYP-STRING
Event-Message Text
Invalid eyecatcher at address. Thread task-name.
Expected eyecatcher, found text