NonStop Operating System Event Management Programming Manual

ServerNet Error Handler Event Messages (ZSNT)
HP NonStop Operating System Event Management Programming Manual520372-020
19-54
Messages
Unconditional Tokens
Conditional Tokens (G-Series Only)
Cause. The interrupt queue was being filled faster than the processor could empty the
queue.
Effect. These interrupts are counted and reported.
Recovery. This is an informational message only; no corrective action is needed.
1034: ZSNT-EVT-LINK-EXCEPT-X-ERRORS
ServerNet link-level protocol errors were detected on the ServerNet X link.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSNT-EVT-
QUEUE-FULL-ERRORS (1033).
ZSNT-TKN-CPU-NUMBER Subject token that specifies the processor that
encountered the error.
ZSNT-TKN-QUEUE-FULL-ERRORS Number of times the queue-full error occurred.
Token Description
ZSNT-TKN-CAUSE-REG Interrupt Cause Register at the time of the exception.
ZSNT-TKN-LINK-XCEPT-X Port X Link Exception Register.
ZSNT-TKN-LINK-XCEPT-Y Port Y Link Exception Register.
Subject: ZSNT-TKN-CPU-NUMBER
Potentially critical event: No
Action event: No
Message sender: GenErr
$ZLOG: Yes
$0: No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSNT-TKN-CPU-NUMBER token-type ZSPI-TYP-INT
ZSNT-TKN-LINK-EXCEPT-X-ERRORS token-type ZSPI-TYP-INT2
Conditional Tokens
ZSNT-TKN-CAUSE-REG token-type ZSPI-TYP-INT2 (G-series)
ZSNT-TKN-LINK-XCEPT-X token-type ZSPI-TYP-INT2 (G-series)
ZSNT-TKN-LINK-XCEPT-Y token-type ZSPI-TYP-INT2 (G-series)