NonStop S-Series Hardware Installation and FastPath Guide (G06.25+)
Troubleshooting
HP NonStop S-Series Hardware Installation and FastPath Guide—529443-001
D-2
Reference
Reference
Power States
This table summarizes the NonStop S-series server power-on, power-off, and 
power-fail/recovery states. For more information about the effects of starting or shutting 
down the server, see the NonStop S-Series Operations Guide. 
6. Rename Software Files Using ZPHIRNM D-29
7. Stop System D-29
8. Load System From Saved Configuration D-30
9. Start Applications D-30
System Consoles D-31
Connectivity Problems D-32
Software Configuration Problems D-36
Software Corruption and Hard-Disk Problems D-37
Restoring Software on the Hard Disk D-38
Configuring a ProCurve 24-Port Ethernet Switch D-48
Topic Page
Power States
D-2
Status LEDs D-4
Server State External Event Result (page 1 of 2)
The server has been shut down 
with SCF or the OSM or TSM 
Low-Level Link. AC power is 
disconnected from the server. 
You reconnect AC 
power to the server.
Power is applied to the server 
components. 
The components complete 
their startup sequence. 
The server is ready for 
system start.
The server has been shut down 
with SCF or the OSM or TSM 
Low-Level Link. AC power 
remains connected to the server. 
You push the power-on 
push button on a PMF 
CRU.
The server components 
complete their startup sequence.
You start the system 
with the OSM or TSM 
Low-Level Link.
The operating system is 
loaded and started. 
The system is ready.
The system is operating 
normally.
You stop the system 
with SCF, OSM, or TSM.
Processing halts. 
Power is disconnected from 
the server components.
Topic Page (page 2 of 2)