NonStop S-Series Hardware Installation and FastPath Guide (G06.26+)
Introduction
HP NonStop S-Series Hardware Installation and FastPath Guide—529876-001
1-51
Installation Overview
Preconfigured IP Addresses
New systems are shipped with preconfigured system IP addresses for system
maintenance that OSM and TSM applications use to communicate with the system.
Note. IOAM components are not pre-configured with IP addresses. IOAM components require
dynamically assigned IP addresses from a DHCP/DNS server, or from software that performs
the same function as that server. For more information, your service provider should refer to
the Modular I/O Installation and Configuration Guide which is located in the NTL Hardware
Service and Maintenance library.
Table 1-6. Preconfigured IP Addresses for a NonStop S-Series Server
Component IP Address Notes
Primary system console 192.231.36.1
•
All system consoles provided by HP are
preconfigured with IP address
192.231.36.1.
•
Two system consoles on the same LAN
cannot use the same IP address.
•
If the primary system console uses IP
address 192.231.36.1, you must change
the IP address on all other new system
consoles before connecting them to the
LAN.
•
The recommended IP address for a
backup system console is 192.231.36.4.
MSP0 192.231.36.2
•
Access is through the Ethernet port on
the PMF CRU in group 01, module 01,
slot 50.
•
This IP address allows you to establish a
low-level link.
MSP1 192.231.36.3
•
Accessed through the Ethernet port on
the PMF CRU in group 01, module 01,
slot 55.
•
This IP address allows you to establish a
low-level link.
NonStop operating system
access using $ZTCP0
192.231.36.10
•
Access is through the Ethernet port on
the PMF CRU in group 01, module 01,
slot 50.
•
This IP address allows you to establish a
service connection.
NonStop operating system
access using $ZTCP1
192.231.36.11
•
Access is through the Ethernet port on
the PMF CRU in group 01, module 01,
slot 55.
•
This IP address allows you to establish a
service connection.