Installing Enclosures
HP NonStop S-Series Hardware Installation and FastPath Guide—540460-001
2-26
Inspect the Components
a. Check that the ejectors on each ServerNet adapter in the enclosure are 
latched.
b. If any ejectors are unlatched, reseat the ServerNet adapter as described next.
9. Perform these steps to reseat each ServerNet adapter that has become improperly 
seated during shipping:
a. Put on your ESD wriststrap and attach the grounding clip securely to an 
exposed, unpainted metal surface, such as the power interlock on a PMF CRU 
or IOMF CRU.
b. Unlatch the ServerNet adapter ejector by pressing the blue-green tab and 
pulling outward on the ejector to unseat the adapter. See Figure 2-22.
c. Grasp the ServerNet adapter ejector with one hand and slide the adapter 
halfway out of the slot.
d. Reinsert the ServerNet adapter until the ejector on the adapter can be 
engaged into the notch on the enclosure.
e. Latch the ServerNet adapter ejector by pressing the blue-green tab and then 
closing the ejector to seat the adapter against the backplane.
10. Repeat Step 1 through Step 9 for all system enclosures.
Figure 2-22. Reseating a ServerNet Adapter
VST960.vsd