NonStop S-Series Hardware Installation and FastPath Guide (G06.27+)
Installing External System Devices
HP NonStop S-Series Hardware Installation and FastPath Guide—540460-001
7-14
Attaching a Tape Drive to the NonStop S-Series
Server
Other manuals for these tape drives are listed in the Third-Party Documentation
Director.
If this documentation collection does not contain the manual for your tape library,
contact your service provider.
Attaching a Tape Drive to the NonStop S-Series Server
To attach a tape drive to any PMF CRU or IOMF CRU:
1. Determine which PMF CRU or IOMF CRU should be connected to the tape drive.
2. Using the SCSI cable connector with the thumbscrews, plug the other end of the
SCSI cable into the differential SCSI port on the appropriate PMF CRU, IOMF
CRU, or IOMF 2 CRU.
•
NonStop S7000, S7400, S70000, and S72000 PMF CRUs and IOMF CRUs
are equipped with an external SCSI passthrough terminator. Attach the SCSI
cable to this SCSI passthrough terminator, which is factory-installed on the
differential SCSI port.
VT5901 Virtual tape
server
Virtual TapeServer Installation Guide (Tape Labs)
(located in the NTL Hardware and Service
Maintenance Collection. See your service provider.)
Virtual TapeServer Operations and Administration
Guide (Tape Labs)
VT5902 Virtual tape
server
Virtual TapeServer Installation Guide (Tape Labs)
(located in the NTL Hardware and Service
Maintenance Collection. See your service provider.)
Virtual TapeServer Operations and Administration
Guide (Tape Labs)
N.A. Any tape drive
attached to a
ServerNet/DA
6760 ServerNet/DA Manual
To Determine the Configuration of ... See ...
Components that are factory-configured The SCF configuration file
($SYSTEM.ZSYSCONF.SCF0000)
printout shipped with your server
A system that has been started, or
components that have been installed and
configured
SCF Reference Manual for G-Series
RVUs
Caution. Never remove the SCSI passthrough terminator from the differential SCSI port. The
SCSI passthrough terminator must be in place to a connect a tape drive to these PMF CRUs or
IOMF CRUs. If it is not present, contact your service provider.