NonStop S-Series Hardware Installation and FastPath Guide (G06.27+)
Powering On and Starting the System
HP NonStop S-Series Hardware Installation and FastPath Guide—540460-001
8-16
Verifying Topology and System Components
If the Topology attribute value (Tetra 8 or Tetra 16) does not match the system 
configuration, you must reset the topology before loading the system. To reset the 
topology, see the OSM Low-Level Link online help or the OSM User’s Guide. 
6. Verify that the system components in the tree pane match the components 
ordered. 
7. From the tree pane, click each system component in the enclosure. The attributes 
for the selected component appear in the details pane. Verify that the value for 
each attribute is as listed in Table 8-3 on page 8-16.
If the Power State attribute for a PMF CRU does not have a value of OK, contact 
your service provider. The PMF CRU is either powered off or contains a fault. 
8. Close the Management window.
9. Optional: Run the SP Tool Application (intended for use only by trained service 
providers) to retrieve detailed information about the system hardware components 
and ServerNet system area network. 
As of the G06.22 RVU, the SP Tool is no longer packaged with TSM. It is now 
packaged with the OSM Low-Level Link or it can be installed independently (from 
the HP NonStop System Console Installer CD) and can be used in conjunction with 
either the OSM or TSM software package. 
Caution. If the Topology attribute value specified in the details pane does not match the 
configuration of the installed system, the view pane might not display all installed enclosures.
Table 8-3. Checking the Attributes of Selected System Components
Tree Pane Example Details Pane: Attributes Tab
Name Value
Double-click each IOMF or IOMF 2 
CRU.
IOMF.GRP-11.
MOD-1.SLOT-50
Power State OK
Click the power supply in each IOMF 
or IOMF 2 CRU.
IOMF.PS.GRP-11.
MOD-1.SLOT-50
Logon State On
Double-click each PMF CRU. PMF.GRP-1.
MOD-1.SLOT-50
Power State OK
Click the processor in the PMF CRU. PROCESSOR-0 Total Memory 
Size
MB should 
match the 
memory 
ordered.
NonStop S7000 servers: click the 
power supply in the PMF CRU.
PMF.PS.GRP-1.
MOD-1.SLOT-50
Logon State On
All NonStop S-series servers except 
the S7000
: click the power supply.
PS.GRP-1.
MOD-1.SLOT-1
Logon State On
Click remaining components. FAN.GRP-1
.MOD-1.SLOT-25
Power State OK