NonStop S-Series Hardware Installation and FastPath Guide (G06.28+)
Troubleshooting
HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001
D-34
System Consoles
Monitor Screen Is Blank
Table D-4. Monitor Screen Is Blank
Symptom Recovery 
The display monitor screen 
appears as if it is switched 
off.
1. Verify that the power switch on the display monitor is in 
the on position and that the display monitor power 
indicator light is lit.
2. Verify that power is available from the power source.
3. Ensure that the display monitor power cord is securely 
connected to the power source.
4. Check that the display monitor interface cable is securely 
attached to its connector on the system unit.
5. Verify that the brightness and contrast controls are 
adjusted to produce a proper display, using the vendor 
documentation as required.
6. Power off the display monitor and system unit.
7. Unplug the display monitor power cord from the power 
source. Examine the cable, connector, and receptacle for 
damage such as connector housing cracks, and frayed or 
broken cable wires and insulation. Reconnect the power 
cord to the power source.
8. Disconnect the display monitor interface cable from the 
system unit, and examine the cable, as in the previous 
step. Reconnect the interface cable.
9. Repair or replace any defective items.
10. Power on the system unit and display monitor and recheck 
the display monitor operation.