NonStop S-Series Hardware Installation and FastPath Guide (G06.29+)

Installing Enclosures
HP NonStop S-Series Hardware Installation and FastPath Guide541880-002
2-23
Inspect the Components
Inspect the Components
Vibration that occurs during shipping or when you move a system can sometimes
dislodge enclosure components or loosen connections to the backplane. Inspect these
components, and reseat those that appear to be improperly seated.
Disk drives
PMF CRUs
IOMF CRUs
SEBs or MSEBs
ServerNet adapters
Perform these steps for each system enclosure:
1. Inspect all disk drives in the system enclosure:
a. Open the enclosure door on the appearance side of the enclosure.
b. Verify that both thumbscrews on the faceplate of each disk drive are tight.
c. If any thumbscrews are loose and if a disk drive appears to be disengaged
from the backplane connector, reseat the disk drive. See Step 2.
2. To reseat each disk drive that has become improperly seated during shipping:
a. Put on your ESD wriststrap and attach the grounding clip securely to an
exposed, unpainted metal surface inside the disk card cage.
b. Simultaneously loosen both thumbscrews on the faceplate of the disk drive
until the CRU disengages from the backplane connector. Do not pull the disk
drive all the way out of the slot. See Figure 2-19.
Figure 2-19. Reseating a Disk Drive
VST985.vsd