NonStop S-Series Hardware Installation and FastPath Guide (G06.29+)

Installing External System Devices
HP NonStop S-Series Hardware Installation and FastPath Guide541880-002
7-16
Installing a SWAN or SWAN 2 Concentrator
NonStop S7000, S7400, S70000, and S72000 PMF CRUs and IOMF CRUs
are equipped with an external SCSI passthrough terminator. Attach the SCSI
cable to this SCSI passthrough terminator, which is factory installed on the
differential SCSI port.
On some CRUs, the SCSI terminator is inside the CRU. In this case, attach the
tape drive cable to the external connector.
The CRUs that contain an internal SCSI terminator include:
°
IOMF 2 CRUs
°
S7x00 and S7x00x PMF CRUs of models S7600 and higher and S7800B
and higher
°
Sxx000 PMF CRUs of model S74000 and higher
3. Tighten the thumbscrews on the cable connector by hand or use a small slotted
screwdriver.
To attach tape drives to a 6760 ServerNet device adapter, see the 6760 ServerNet/DA
Manual.
Installing a SWAN or SWAN 2 Concentrator
The ServerNet wide area network (SWAN) concentrator communications device or the
SWAN 2 concentrator communications device connects to a server using a pair of
Ethernet local area networks (LANs). The SWAN concentrator or the SWAN 2
concentrator provides WAN connections supporting both synchronous and
asynchronous data over a variety of electrical interfaces. The SWAN concentrator or
the SWAN 2 concentrator can be installed in a 19-inch rack or on a desk or tabletop.
Install the SWAN concentrator or the SWAN 2 concentrator after the system is
powered on, tested, and running the operating system. For information about installing
or configuring a SWAN concentrator, see the SWAN Concentrator Installation and
Support Guide. For information about installing or configuring a SWAN 2 concentrator,
see the SWAN 2 Concentrator Installation and Support Guide.
You can install any SWAN or SWAN 2 concentrator by using the WAN Wizard Pro
application. Depending on the RVU, you gain access to the WAN Wizard Pro through
the taskbar on your system console by using one of these methods:
For G06.21 RVU and later RVUs:
Start>Programs>HP WAN Wizard Pro>WAN Wizard Pro
For G06.20 RVU and earlier RVUs:
Start>Programs>Compaq TSM>Guided Configuration Tools>WAN Wizard
Caution. Never remove the SCSI passthrough terminator from the differential SCSI port. The
SCSI passthrough terminator must be in place to a connect a tape drive to these PMF CRUs or
IOMF CRUs. If it is not present, contact your service provider.