Powering On and Starting the System
HP NonStop S-Series Hardware Installation and FastPath Guide541880-002
8-12
Troubleshooting Abnormal LED States
Troubleshooting Abnormal LED States
Hardware or software faults can prevent the green power-on LED on a CRU from
lighting when power is applied. If the amber service LED for a CRU lights and remains
lit, the CRU cannot be accessed. A fault might have been detected, or the CRU might
not have been successfully initialized and configured for use as a system resource.
Note. For troubleshooting abnormal LED states displayed in IOAM enclosures or FCDMs,
contact your service provider trained by HP.
Table 8-2. Troubleshooting Abnormal LED States (page 1 of 2)
Location LED State Action
System
enclosure
Group service LED is
flashing.
Check the group ID switch settings for all enclosures
in the system:
Settings for the two switches within any enclosure
must be the same.
Settings for any two enclosures must be different.
Change the switch settings, if necessary, using the
information about adding a processor enclosure in the
NonStop S-Series System Expansion and Reduction
Guide.
In OSM, the action is Set Service LED State, which
sets the state to On or Off. In TSM, the actions are
Set Group Service LED and Clear Group Service
LED.
PMF CRU Amber service LED is
lit.
With the OSM or TSM Event Viewer, check the EMS
log files for pertinent event messages.
Retry the operation.
Replace the PMF CRU if necessary. See:
PMF CRU and IOMF CRU Power-On Self-Tests
on page 1-57
OSM Guided Replacement Procedures on
page xxiv
TSM Guided Replacement Procedures on
page xxv