NonStop S-Series Hardware Installation and FastPath Guide (G06.29+)

Performing Post-Startup Tasks
HP NonStop S-Series Hardware Installation and FastPath Guide541880-002
9-14
Restarting the Inspect Monitor Process
Restarting the Inspect Monitor Process
If Visual Inspect is installed on your system, then on the G05 and later RVUs, $ZPM
automatically starts the Inspect Monitor process $IMON early in the system startup
sequence to provide Inspect debugging and saveabend file capability. However, Visual
Inspect requires that $IMON be started after the TCP/IP and Port Mapper processes
have started.
After $ZPM has started all processes specified in the CONFIG file and you start all
other TCP/IP and Port Mapper processes, stop and restart $IMON as follows:
1. Log on as the super ID.
2. At the TACL prompt:
> Stop $IMON
3. At the TACL prompt, restart $IMON:
> IMON /name $IMON, term $YMIOP.#CNSL, cpu <p>, nowait /<b>
where <p> and <b> are the primary and backup processors, respectively, where
$IMON is to run.
Change time attributes. X
Configure and initialize the spooler subsystem.
See the Spooler Utilities Reference Manual
and the Guardian Users Guide.
X
Configure the IOAM enclosure. X
Configure and start additional subsystems.
See the manual specific to that subsystem.
X
Table 9-1. System Configuration Changes and Verifications (page 2 of 2)
Change or Verification Required Recommended
Optional or
As Needed