CP6100 Lines Shutdown File
CP6100 Lines Shutdown File
This example shows an SCF command file that stops the ATP6100 lines associated
with the SWAN concentrator $ZZWAN.#S01 (configuration track-ID X001XX).
This file can be invoked automatically from the STOPSYS file, or you can invoke it by
using the following TACL command:
> SCF/ IN $SYSTEM.SHUTDOWN.SDNCP6, OUT $ZHOME /
== This is $SYSTEM.SHUTDOWN.SDNCP6
== This shuts down the CP6100 lines associated with the SWAN concentrator
== $ZZWAN.#S01
ALLOW 20 ERRORS
ABORT LINE $cp6*
ATP6100 Lines Shutdown File
This example shows an SCF command file that stops the ATP6100 lines associated
with the SWAN concentrator $ZZWAN.#S01 (configuration track-ID X001XX).
This file can be invoked automatically from the STOPSYS file, or you can invoke it by
using the following TACL command:
> SCF/ IN $SYSTEM.SHUTDOWN.SDNATP, OUT $ZHOME /
== This is $SYSTEM.SHUTDOWN.SDNATP
== This shuts down the ATP6100 lines associated with the SWAN concentrator
== $ZZWAN.#S01
ALLOW 20 ERRORS
ABORT LINE $ATP*
X.25 Lines Shutdown File
This example shows an SCF command file that stops the X.25 lines associated with
the SWAN concentrator $ZZWAN.#S01 (configuration track-ID X001XX).
This file can be invoked automatically from the STOPSYS file, or you can invoke it by
using the following TACL command:
> SCF/ IN $SYSTEM.SHUTDOWN.SDNX25, OUT $ZHOME /
== This is $SYSTEM.SHUTDOWN.SDNX25
== This shuts down the X.25 lines associated with the SWAN concentrator
== $ZZWAN.#S01
ALLOW 20 ERRORS
ABORT LINE $X25*