NonStop S-Series Hardware Installation and FastPath Guide (G06.29+)

Case Study: Installing and Configuring a System
HP NonStop S-Series Hardware Installation and FastPath Guide541880-002
14-30
Adding an ATP6100 Line
Adding an ATP6100 Line
This example contains an SCF command file that adds an ATP6100 line associated
with the SWAN concentrator $ZZWAN.#S01 (configuration track-ID X001XX) to the
configuration database. This line can be used to connect an asynchronous terminal
that uses the RS-232 interface. It also contains a startup file.
== This is $SYSTEM.STARTUP.ADDATP
== This file should be invoked after ADDMGR,
== and ADDSWAN.
== Add and start an ATP6100 device
allow 20 errors
ADD PROFILE $ZZWAN.#prof6530, FILE $SYSTEM.sys00.PATP6530
ADD DEVICE $ZZWAN.#atpp1, &
CPU 0, &
ALTCPU 1, &
PROFILE prof6530, &
IOPOBJECT $system.sys00.oatpcss, &
TYPE (53,00), &
RECSIZE 150, &
CLIP 2, &
LINE 1, &
ADAPTER s01, &
PATH A
START DEVICE $ZZWAN.#S01
== To enable data communications, you must start the lines using
== the command START LINE $atpp1 or by invoking a startup file that
== contains this command.
== To start a process, such as a TACL process, on this line
== specify $ATPP1.#TERM.