3. Connect AC Power Cords
3. Connect AC Power Cords
Enclosures Without Power Shelves
1. Find the detachable AC power cords included with your system.
2. Start with the group 01 processor enclosure.
3. Make sure the power interlock on the PMF CRU or IOMF CRU in slot 50 or 55 is
fully engaged so that the power cord retainer is aligned with the power receptacle.
4. Connect the AC power cord to the power receptacle on the PMF CRU or IOMF
CRU.
5. Using a stubby Phillips screwdriver, secure the power cord plug in the power cord
retainer by tightening the retainer screw.
6. Repeat Steps 3 through 5 for the other AC power cord for this enclosure and for all
remaining enclosures without power shelves.
Caution. Do not plug the other end of the AC power cord into the dedicated outlet at this time.
Doing so immediately powers on the PMF CRU or IOMF CRU.