NonStop S-Series Hardware Installation and FastPath Guide (G06.29+)

FastPath Tasks: Required
HP NonStop S-Series Hardware Installation and FastPath Guide541880-002
E-44
5. Configure DSM/SCM
5d. Configure Target Information for Host’s Logical Target
1. Run ZPHITMI from the ZDSMSCM subvolume.
> VOLUME $DSMSCM.ZDSMSCM
> RUN ZPHITMI
2. Log on to the target Maintenance Interface using the super ID.
3. Add operators and their security:
a. In the Maintenance Interface main menu, select 3 (Security Maintenance
Menu). Press F1.
b. In the Security Maintenance Menu, select 1 (Operator Security Maintenance).
c. In the Operator Security Maintenance screen, add the appropriate operators as
instructed by the interface, specifying which DSM/SCM tasks each operator
can perform. When all operators are added, press F16 twice to return to the
main menu.
4. Press Shift-F16 to exit the target Maintenance Interface.
5e. Restart Inspect Monitor Process
If Visual Inspect is installed on your system, for the G05 and later RVUs, $ZPM
provides Inspect debugging and saveabend file capability by automatically starting the
Inspect Monitor process $IMON early in the system startup sequence. However, Visual
Inspect requires that $IMON be started after the TCP/IP and Port Mapper processes.
After $ZPM has started all processes specified in the CONFIG file, and you start all
other TCP/IP and Port Mapper processes, stop and restart $IMON as follows:
1. Log on as the super ID.
2. At the TACL prompt, stop $IMON by entering:
> Stop $IMON
3. At the TACL prompt, restart $IMON by entering:
> IMON /name $IMON, term $YMIOP.#CNSL, cpu p, nowait /b
where p and b are the primary and backup processors, respectively, where $IMON
is to run.
Note. The super ID is already set up as an operator.