NonStop S-Series Operations Guide (G06.24+)
Overview of Monitoring and Recovery
HP NonStop S-Series Operations Guide—522459-007
3-21
Using SCF to Locate the Problem
You decide to do some more research, this time using SCF.
Using SCF to Locate the Problem
Because the error messages and the alarm detail indicate a problem with the Y fabric,
you issue an SCF STATUS SERVERNET command:
> SCF STATUS SERVERNET $ZSNET
The system displays:
NONSTOP KERNEL - Status SERVERNET
X-FABRIC
TO 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
FROM
00 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
01 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
02 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
03 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
04 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
05 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
06 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
07 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
08 <- DOWN
09 <- DOWN
10 <- DOWN
11 <- DOWN
12 <- DOWN
13 <- DOWN
14 <- DOWN
15 <- DOWN
Y-FABRIC
TO 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
FROM
00 UP UP UP UP DN DN UP UP UNA UNA UNA UNA UNA UNA UNA UNA
01 UP UP UP UP DN DN UP UP UNA UNA UNA UNA UNA UNA UNA UNA
02 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
03 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
04 DN DN UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
05 DN DN UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
06 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
07 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
08 <- DOWN
09 <- DOWN
10 <- DOWN
11 <- DOWN
12 <- DOWN
13 <- DOWN
14 <- DOWN
15 <- DOWN