NonStop S-Series Operations Guide (G06.27+)

Overview of Monitoring and Recovery
HP NonStop S-Series Operations Guide522459-008
3-22
Using SCF to Locate the Problem
The system displays:
The boldface output in the display shows that the Y-fabric connection between the
processors in group 01 (processors 0 and 1) and the processors in group 03
(processors 4 and 5) is down. The X fabric is functioning normally. Because the UP
values in the display show that all the processors are able to communicate with other
NONSTOP KERNEL - Status SERVERNET
X-FABRIC
TO 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
FROM
00 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
01 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
02 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
03 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
04 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
05 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
06 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
07 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
08 <- DOWN
09 <- DOWN
10 <- DOWN
11 <- DOWN
12 <- DOWN
13 <- DOWN
14 <- DOWN
15 <- DOWN
Y-FABRIC
TO 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
FROM
00 UP UP UP UP DN DN UP UP UNA UNA UNA UNA UNA UNA UNA UNA
01 UP UP UP UP DN DN UP UP UNA UNA UNA UNA UNA UNA UNA UNA
02 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
03 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
04 DN DN UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
05 DN DN UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
06 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
07 UP UP UP UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
08 <- DOWN
09 <- DOWN
10 <- DOWN
11 <- DOWN
12 <- DOWN
13 <- DOWN
14 <- DOWN
15 <- DOWN