NonStop S-Series Operations Guide (G06.27+)
Disk Drives: Monitoring and Recovery
HP NonStop S-Series Operations Guide—522459-008
9-7
Monitoring Disk Drives With SCF
2. Get information about a disk with SCF STATUS DISK, DETAIL. For example:
-> STATUS DISK $DATA09, DETAIL
The output from this example shows that $DATA09 is in the STOPPED state, 
HARDDOWN substate.
3. See Recovery Operations for a Down Disk or Down Disk Path on page 9-15.
Examples
To display the status of the disk $DATA01:
-> STATUS $DATA01
To display the status of the mirror path of the volume $DATA02:
-> STATUS $DATA02-M
65-> SCF STATUS DISK $DATA09, DETAIL
SCF - T9082G02 - (30JUN97) (14MAY97) - 11/05/98 13:24:10 System \SHARK
STORAGE - Detailed Status DISK \SHARK.$DATA09
Disk Path Information:
 LDev Path    Status  State  Substate  Primary Backup
            PID   PID
 92 PRIMARY   INACTIVE  STOPPED HARDDOWN  2,266  3,266
 92 BACKUP   INACTIVE  STOPPED HARDDOWN  2,266  3,266
 92 MIRROR   INACTIVE  STOPPED HARDDOWN  2,266  3,266
 92 MIRROR-BACKUP INACTIVE  STOPPED HARDDOWN  2,266  3,266
General Disk Information:
 Device Type........... 3  Device Subtype........... 40
 Primary Drive Type....  Mirror Drive Type........
 Physical Record Size.. 4096  Priority................. 220
 Library File..........
 Program File.......... $SYSTEM.SYS00.TSYSDP2
 Protection............ MIRRORED
Hardware Information:
 Path   Location   Power   Physical Status
  (group,module,slot)
 PRIMARY   (2,1,1)   DUAL   PRESENT
 MIRROR   (2,1,2)   NONE   ABSENT
Total Errors = 0 Total Warnings = 0     
34-> STATUS $DATA01
STORAGE - Status DISK \SHARK.$DATA01
LDev  Primary  Backup Mirror  MirrorBackup Primary  Backup
           PID  PID
 63  *STARTED  STARTED *STARTED  STARTED  0,267  1,266
47-> STATUS DISK $DATA02-M
STORAGE - Status DISK \SHARK.$DATA02-M
LDev  Path   PathStatus State  SubState  Primary Backup
            PID  PID
 62 MIRROR   INACTIVE STOPPED  HARDDOWN  0,268  1,265