NonStop S-Series Operations Guide (G06.29+)
Overview of Monitoring and Recovery
HP NonStop S-Series Operations Guide—522459-009
3-33
Using the Status LEDs to Monitor the System
Gigabit Ethernet 
4-port ServerNet 
adapater (G4SA)
Power-on Green Lights when the adapter is receiving 
power.
Service Amber Lights to indicate internal failure or 
service action required. 
ServerNet switch 
board
Power-on Green Lights when the adapter is receiving 
power.
Service Amber Lights to indicate internal failure or 
service action required. 
ServerNet 
expansion board 
(SEB) or 
modular 
ServerNet 
expansion board 
(MSEB)
Power-on Green Lights when the SEB or MSEB is 
receiving power.
Fault Amber At initial power on, lights until the SEB or 
MSEB has been successfully configured 
by the service processor (SP). Then the 
LED goes off.
Lights continuously to indicate that the 
SEB or MSEB is not in a fully functional 
state. 
ServerNet port: Amber 
(6 on SEB)
Green (10 
on MSEB)
Unused.
Indicates state of the ServerNet link. 
Light on indicates that the port is 
receiving a valid link-alive signal from the 
remote port to which the PIC is 
connected. Light extinguishes on loss of 
the link-alive signal.
System 
enclosure
Group service 
(2 in each 
enclosure)
Amber On or off in response to a group service 
LED command from OSM or TSM.
Table 3-5. Status LEDs and Their Functions (page2of2)
Location LED Name Color Function