Monitoring the ServerNet Fabrics Using SCF
°
The status from proce ssors 2 throu gh 15 is displa ye d as dow n.
Normal ServerNet Fabric States
Normal states for a path on the ServerNet fabrics can be one of:
•
UP
The path from the processor in the FROM row to the processor in the TO column
is up. The status for all ServerNet connections between existing processors in a
system should be UP.
•
<-DOWN (for an entire row)
The processor in the FROM row is down or nonexistent. If the processor in the
FROM row does not exist on your system, this status is normal. Otherwise, refer
to Identifying ServerNet Fabric Problems on page 12-5.
•
UNA (unavailable)
The processor in the TO column is down or nonexistent. Therefore, the path from
the processor in the FROM row to the processor in the TO column is down. If the
processor in the TO column does not exist on your system, this status is normal.
Otherwise, refer to Identifying ServerNet Fabric Problems on page 12-5.